Free Standard Shipping on Water Heaters shipped within the Mainland Continental United States
- Capacities from 6 – 50 gallons
- Goldenrod 24-carat heating elements resist scale build-up
- Most models convert to three-phase or single-phase in field for easy installation
- Individual internal element fusing for greater reliability
- Capacities from 30 – 119 gallons
- Goldenrod 24-carat heating elements resist scale build-up
- Most models convert to three-phase or single-phase in field for easy installation
- Individual internal element fusing for greater reliability
- Capacities from 6 – 119 gallons
- Goldenrod 24-carat heating elements resist scale build-up
- Most models convert to three-phase or single-phase in field for easy installation
- Individual internal element fusing for greater reliability
- Booster models increase temperature from 140° to 180° F for sanitizing dishwater in food service applications
- Simplified circuitry — color-coded for easier servicing
- R-16 foam insulation provides extra protection against heat loss
- Rugged magnetic contactors UL rated for 100,000 cycles
- Capacities from 6 – 119 gallons
- Goldenrod 24-carat heating elements resist scale build-up
- Most models convert to three-phase or single-phase in field for easy installation
- Individual internal element fusing for greater reliability
- 66, 80, and 119 gallon sizes are designed for light duty commercial applications with intermittent hot water loads.
- The standard voltage is 240V single phase.
- Two 4.5 KW zinc plated copper sheathed elements are standard.
- Thermostat is adjustable through a range of 120° to 181°F with a manual reset high temperature cutoff. The heater is wired for non-simultaneous single phase operation.
- Our COREGARD™ anode rods have a stainless steel core that extends the life of the anode rod allowing superior tank protection for longer than standard anode rods.
- Meets the standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IES 90.1.
- 3-year limited tank warranty
- System Sentinel™ L.E.D. diagnostic system
- Surface mounted and immersion thermostat models available
- Lifeguard stainless steel elements 208, 240, 277 and 480 voltages
- Manual reset high limit control
- Magnetic contactors and integral fusing
- Hot outlet and cold inlet are 1-1/2" NPT dielectric nipples which prevent excessive turbulence of heated water and results in optimum tank draw.
- 3" Rigid foam insulation.
- Heavy duty anode rods
- Full port, full blow, brass drain valve
- Factory Installed AGA/ASME rated Temperature and Pressure relief valve
- 208, 240, 277 and 480 voltages
- Porcelain enamel-lined tank
- Heavy duty anode rod
- Foam insulation, for reduced operating costs
- Baked enamel steel jacket
- Patented resistor heating elements
- Surface-mounted thermostat
- Manual reset high-limit control
- Durable brass drain valve
- AGA/ASME-rated Temperature /Pressure relief valve
- 208, 240, 277 and 480 voltages
- Porcelain enamel lined tank
- Heavy duty anode rod
- Foam insulation, for reduced operating costs
- Baked enamel steel jacket
- Patented resistor heating elements
- Surface-mounted thermostat
- Manual reset high-limit control
- Durable brass drain valve
- AGA/ASME-rated Temperature /Pressure relief valve
- System Sentinel™ L.E.D. diagnostic system
- Surface mounted and immersion thermostat models available
- Lifeguard stainless steel elements 208, 240, 277 and 480 voltages
- Manual reset high limit control
- Magnetic contactors and integral fusing
- Hot outlet and cold inlet are 1-1/2" NPT dielectric nipples which prevent excessive turbulence of heated water and results in optimum tank draw.
- 3" Rigid foam insulation.
- Heavy duty anode rods
- Full port, full blow, brass drain valve
- Factory Installed AGA/ASME rated Temperature and Pressure relief valve
<p><span style="font-size: 11px;">System Sentinel™ L.E.D. diagnostic system</span></p>
</li>
<li>
<p><span style="font-size: 11px;">Immersion Thermostat</span></p>
</li>
<li>
<p><span style="font-size: 11px;">Lifeguard stainless steel elements</span></p>
</li>
<li>
<p><span style="font-size: 11px;">208, 240, 277, and 480 voltages</span></p>
</li>
<li>
<p><span style="font-size: 11px;">Manual reset high limit control</span></p>
</li>
<li>
<p><span style="font-size: 11px;">Magnetic contactors and integral fusing</span></p>
</li>
<li>
<p><span style="font-size: 11px;">Hot outlet and cold inlet are 3/4" NPT plastic lined nipples
which prevent excessive turbulence of heated water and results in
optimum tank draw</span></p>
</li>
<li>
<p><span style="font-size: 11px;">85% of the tank surface area of all Rheem-Ruud Commercial
Electric products are insulated with 2-1/2" of rigid polyurethane foam
insulation</span></p>
</li>
<li>
<p><span style="font-size: 11px;">Heavy duty anode rods</span></p>
</li>
<li>
<p><span style="font-size: 11px;">Full port, full flow brass drain valve</span></p>
</li>
<li>
<p><span style="font-size: 11px;">Factory installed AGA/ASME rated Temperature and Pressure relief valve</span></p>
</li>
</ul>